Insulation: Glass reinforced phlogopite mica
tapes. A fiberglass braid jacket is applied over the insulation, then
treated with a high temperature saturant. Natural color is tan. Other
colors available on request.
Applications: Used for internal wiring of domestic and commercial
ovens as well as cooking appliances. Also ideal for use in electric
heaters and for equipment wiring in iron mills, glass plants and cement
kilns.
Approvals: UL style as listed. CSA AWM Class I - Group A/B.
Awg
Stranding
Insulation
Thickness
Braid
Thickness
Overall
Diameter
Amps
Weight
Lbs / Mft
Temperature
Rating
20
10/.0100
0.025
.007
0.105
23
10
450ºC
18
16/.0100
0.025
.007
.0115
31
12
450ºC
16
26/.0100
0.025
.007
0.125
40
16
450ºC
14
41/.0100
0.025
.007
0.140
55
23
450ºC
12
65/.0100
0.025
.007
0.160
75
31
450ºC
10
105/.0100
0.030
.017
0.210
100
52
450ºC
8
133/.0111
0.030
.017
0.265
130
78
450ºC
6
133/.0142
0.030
.017
0.310
175
115
450ºC
4
133/.0177
0.030
.017
0.365
235
175
450ºC
2
133/.0223
0.035
.020
0.450
315
260
450ºC
1
259/.0177
0.035
.020
0.490
420
320
450ºC
1/0
259/.0202
0.035
.020
0.535
490
400
450ºC
2/0
259/.0229
0.035
.020
0.590
580
505
450ºC
3/0
259/.0255
0.035
.020
0.650
675
620
450ºC
4/0
259/.0286
0.035
.020
0.710
785
760
450ºC
250
MCM
427/.0255
0.040
.020
0.775
865
915
450ºC
350
MCM
427/.0286
0.040
.020
0.890
1075
1250
450ºC
500
MCM
427/.0342
0.040
.020
1.045
1400
1770
450ºC
Dimensions and weights shown are nominal,
subject to industry tolerances.